Lipontšo le Metara ea Matla
Tlhaloso ea Mofuta
Mofuta | Ntho | Mokhoa oa ho bonts'a | Matla | Ho notlela single | Ho notlela mabitso a mabeli | Kenya | Boiketsi | Boemo | Ho khaola boholo | Setšoantšo | |
hlahloba | tshoanya | hlahloba | |||||||||
Mofuta o hahiloeng | GPXN-Q | Tobetsa konopo | - | 96×48×88 | 91×44 | 3 | |||||
GPXN-T | Tobetsa konopo | 96×48×55 | 91×44 | 3 | |||||||
Swg. | GPXN1-Q | Khanya | - | - | 96×48×88 | 91×44 | 1 | ||||
GPXN1-T | Khanya | - | 96×48×55 | 91×44 | 1 | ||||||
GPXN4-Q | Tobetsa konopo | - | - | 144×48×104 | 138×44 | 4 | |||||
GPXN4-T | Tobetsa konopo | - | 144×48×104 | 138×44 | 4 | ||||||
GPXN5-Q | Tobetsa konopo | - | - | 96×48×88 | 91×44 | 2 | |||||
GPXN5-T | Tobetsa konopo | - | 96×48×55 | 91×44 | 2 | ||||||
Insulator e le 'ngoe e nang le Lipontšo tse 2 | GPXN4-Q/M | Tobetsa konopo | - | - | 144×48×104 | 138×44 | 4 | ||||
GPXN4-T/M | Tobetsa konopo | - | 144×48×104 | 138×44 | 4 | ||||||
GPXN4-T/Z | Tobetsa konopo | 144×48×104 | 138×44 | 4 | |||||||
Mofuta o Ikgethileng | GPXN1-Q/CS | Khanya | - | - | - | 96×48×88 | 91×44 | ||||
GPXNP1-Q/W | Khanya | - | - | - | 96×48×88 | 91×44 | 1 | ||||
GPXN-Q/LCS | Khanya | - | - | 96×48×88 | 91×44 | 3 |
Letšoao la Voltage le Sebelisitsoeng Karolong e ka Sehloohong ea Ring
Letšoao la motlakase le sebelisoa hammoho le insulator ho bonts'a boemo ba motlakase oa potoloho ea motlakase.
Motlakase o sa khaotseng oa GPXN9-C o sebelisoa le indicator ho bontša boemo ba motlakase.Sebaka sa lesoba la terminal ea ho hlahloba matla ke 14mm kapa 19mm.
Phase comparator GPXN-C e sebelisoa le indicator ho bontša boemo ba motlakase oa motlakase o phahameng le ho hlahloba tatellano ea karolo ea lisebelisoa tsa motlakase.
Tlhokomelo ea matla: sebapisi sa mohato se kentsoeng ka har'a lefatše kapa li-terminals tse ling tsa lisebelisoa tsa motlakase o phahameng.
Phase-check: phase comparator e kenya ka har'a seteishene sa tlhahlobo ea motlakase ea karolo e le 'ngoe ea lisebelisoa tse peli tsa motlakase o phahameng, haeba lebone la LED le khanya, ho bontša hore mohato oa tlhahlobo o na le phepelo ea motlakase.
Pontšo ea Boemo
Position indicator e ka etsisa boemo ba ts'ebetso le boemo ba lisebelisoa tsa switch joalo ka switch le sekhechana sa potoloho tsamaisong ea motlakase.E sebelisoa haholo mefuteng eohle ea boto ea ho etsisa ea kamore e bohareng ea taolo le phanele ea switchgear setsing sa motlakase, seteisheneng sa motlakase le seteisheneng sa transformer.Letoto lena la matšoao a boemo bo na le ts'epo e phahameng, mefuta e mengata ea matla a ho sebetsa le nako e telele ea bophelo.DC le AC li fumaneha bakeng sa tšebeliso.
Tekheniki Parameters
Matla a lekantsoeng | DC/AC 98V~242V |
Matla a khanyang | >40 cd/㎡ |
Maqhubu a matla a mamella voltage | 2kV/1 mets |
Insulation resistance | ≥100MΩ |
Ho felloa ke matla | ≤1W |
Mocheso oa ho sebetsa | -15 ℃ ho +50 ℃ |
Bolele ba bophelo | lilemo tse 10 |
Tshebetso ya pontsho | Boemo ba ho sebetsa bo bonts'oa ka 'mala o mofubelu / o motala le litšoantšo (Joaloka khetho ea bareki) |
Bophahamo ba Outline: | 37.5×37.5×62(mm) |
Boholo ba ho seha: | Φ25(mm) |
Mohlala | Tlhaloso |
GPWZ25-K/2 | Position-Position-Breaker |
GPWZ25-E/1 | Position Indicator-Earthing Switch |
GPWZ25-B/2 | Teraka ea ho Tšoara Sesupo sa Boemo |
GPWZ25-B/1 | Position ea boemo-Sehokelo |
GPWZ25-K/1 | Position ea boemo-Tse fetola maemo a mararo |
Boemo bo Bontšang Screen GPAS-72
Sebaka sa serial sa GPAS-72 se bontšang skrine se amohelang LED e le mohloli oa leseli, ka tšebeliso e tlaase ea matla, botšepehi bo phahameng, bophelo bo bolelele ba tšebeletso, joalo-joalo 'me e ka sebelisoa ho mefuta eohle ea li-switchgears e le boemo bo bontšang skrine ka tharollo e fapaneng ea setšoantšo sa tsamaiso.Ka mesebetsi e mengata ea pontšo ea phase-voltage, interlock, mocheso le taolo ea mongobo, pontšo ea boemo ba koloi ea letsoho, pontšo ea boemo ba potoloho ea potoloho, pontšo ea boemo ba lefatše, pontšo ea matla a bolokiloeng.Ke khetho e ntle ea ho nka sebaka sa sesupo sa boemo ba boemo ba single switch.
Tekheniki Parameters
Matla a lekantsoeng | AC/DC 110V/220V |
Maqhubu a matla a matla | 2kV/mots |
Tikoloho ya mosebetsi | -25 ℃ ho 55 ℃, ≤90%RH |
Leseli la lebone la Analog | >40cd/m2 |
Bophelo ba ho sebetsa | 10 lilemo |
Boemo ba ts'ireletso | IP42 |
Boemo | 199x146x63mm |
Ho khaola boholo | 177x121 limilimithara |
Tekheniki ParametersGpj-3100 Series Short Circuit And Earth Fault Indicator
Letoto la GPJ-3100 la potoloho e khuts'oane le sesupo sa phoso ea lefats'e li etselitsoe tlhahlobo le ho bonts'a potoloho e khuts'oane le phoso ea lefats'e ka nako ea nnete.E sebelisoa ho lekola potoloho ho RMU, mohala o holimo, mohala oa phepelo ea thapo ea matla, mochini oa mofuta oa lebokose le libaka tse ling tse tšoanang.Ho ea ka pontšo ea alamo e bontšitsoeng ke indicator, basebetsi ba ka tseba le ho khaola sebaka sa phoso ka potlako ha potoloho e khutšoanyane kapa phoso ea lefats'e e etsahala sebakeng sa potoloho, kahoo tsamaiso e ka khutlisa matla a ho fana ka matla sebakeng se se nang phoso ho boloka nako le ho ntlafatsa ts'ebetso.
Lintlha tsa Tekheniki
1. Potoloho e khuts'oane e tšosang hona joale: 100A ho 1000A nako ea ho lieha 40ms
2. Lefatše le tšosang hona joale: 20A, 30A, 40A, 50A, 60A± 10% nako ea ho lieha 40ms
3. Mocheso o fapaneng : -25 ho +70 ℃
4. Boemo ba mongobo: ≦95%
5. Bolelele ba pele ba lefats'e: 4m
6. Etsa optical fiber bolelele ba 3.5m
7. Matla a matla: lithium battery 3.6V/2.45Ah
8. Auto-reset nako : 7s, 2hrs, 4hrs,8hrs
9. Phetiso ea tlhahiso : 120 V AC 1A, 30V DC 2A
10.Main controller dimension : 95x50x80mm
11.Ho khaola sekoti sa boholo : 91x44 mm
12.Sehlopha sa tšireletso : Molaoli ea ka Sehloohong :IP40, Sensor: IP65