GPN1-12kV Removable AC Metal-clad Enclosed Switchgear
Boemo ba tikoloho
Mocheso oa tikoloho: -25 ℃~+45 ℃, karolelano ea letsatsi le letsatsi: ≤35 ℃
Bophahamo: 1000m( Standard);e ka fihla ho 4500m bakeng sa ho odara ho khethehileng;
Mongobo o amanang: karolelano ea letsatsi le letsatsi ≤95%, karolelano ea khoeli le khoeli ≤90%;
Matla a tšisinyeho ea lefatše ≤8 degree;
Liketsahalo tse sebetsang ha lia lokela ho ba le lintho tse ka tukang, liqhomane, lintho tse senyang le ho thothomela ho matla.
Mohlala

Sebopeho sa lihlahisoa
1) Sehlahisoa sena se sebetsa bakeng sa GPVN-12kV/17Kv/24kV ea rona e kentsoeng kapa e sireletsang sekhechana sa potoloho ea vacuum kapa sekhechana sa ABB sa VD4.
2) Sebopeho sa rona sa tlhahiso ea GPVC vacuum contactor - motsoako oa fuse kapa li-vacuum contactors tsa VC tsa k'hamphani ea ABB, tse ka entsoeng ka FC loop cubicle, ho finyella tsamaiso ea motlakase ea limela tsa matla le tlhokahalo ea likhoebo tse ling tsa indasteri le tsa merafo.
3) Ho sebelisa poleiti ea tšepe e entsoeng ka aluminium-zinki e ntle haholo ka lisebelisoa tsa machining tsa CNC tse bokelletsoeng ka har'a khabinete, le ts'ebeliso ea ts'ebetso ea ho kobeha habeli, ho ntlafatsa matla a khabinete haholo.
4) Sebaka sa monyako ka epoxy resin electrostatic powder spray process, ho hanyetsa ha kutu, oxidation, tšusumetso le ho khomarela ka matla.
5) Sebopeho sa Kabinete se koaletsoeng ka botlalo se hlokomeloa ka lihlomo tse felletseng, likarolo tse sebetsang li arohane ka botlalo.Ha lemati le koetsoe, le ka finyella ts'ebetso ea potoloho ea potoloho le switching earthing.
6) Mokhoa o nepahetseng oa screw drive, etsa bonnete ba hore trolley e na le phetoho e ntle.
7) Morero o phethahetseng oa mantlha oa ho fihlela litlhoko tse fapaneng tsa basebelisi, 'me o nolofalletsa moralo oa trolley habeli.
8) Sesebelisoa sa ho theola fatše ka potlako bakeng sa lipotoloho tsa lefatše le tse khutšoane, le ho fihlela ts'ebetso ea motlakase (Motorized).
9) Mokhoa o bonolo le o sebetsang oa ho notlela "Five Safety" o ka thibela ts'ebeliso e mpe le ho netefatsa polokeho ea opareitara.
10) Switchgear ke ea mofuta oa Arc-proof, ka holim'a kamore ea libese, kamore ea "Vacuum circuit breaker", 'me kamore ea li-cable terminal e na le lisebelisoa tsa liphallelo.
11) Kamore ea li-cable e na le sebaka se lekaneng, e ka kopanngoa habonolo le lithapo tse ngata, 'me e etsa bonnete ba hore bophahamo ba ho kenya plug ea cable.
12) Tekanyetso e tiileng ea tšireletso (IP4X), ho thibela ka katleho lintho tse tsoang linaheng tse ling kapa tlhaselo ea likokoanyana.
13) Sistimi ea bobeli ea boikhethelo e latelang sesebelisoa sa ts'ireletso ea ts'ireletso e na le ts'ebetso ea ho itlhahloba le puisano ea data, komporo e kopaneng e bohlale, ho fihlela taolo e hole, telemetry e hole, ho shebella hole, phetoho e hole.
14) Kopana le litekanyetso tsa GB3906, GB / T11022, DL404 le IEC60298, IEC62271-1, le ka tlhahlobo e felletseng ea tlhahlobo le tlhahlobo ea sehlaba (3000 m).
15) E fetisitse liteko tsa tšebelisano ea motlakase ka laboratoring ea liteko tsa lisebelisoa tse phahameng.
Tlhaloso ea A.Technical Bakeng sa 12Kv switchgear
Ntho | Yuniti | Lintlha | |
Matla a lekantsoeng | kV | 6-12 | |
E lekantsoe khafetsa | Hz | 50/60 | |
E lekantsoe hajoale | A | 630-4000 | |
Boemo bo lekantsoeng ba insulation | 1min maqhubu a matla (Mohato ho ea lefats'eng / ka har'a mabitso a bulehileng) | kV | 42/48 |
Tšusumetso ea lehalima e mamella voltage (Mohato ho ea lefats'eng / ho pholletsa le mabitso a bulehileng) | kV | 75/85 | |
Main busbar rated current | A | 1250,1600,2000,2500,4000 | |
Sub-busbar e na le lintlha tsa hajoale | A | 630,1250,1600,2000,2500,3150 | |
E fuoe lintlha tsa nako e khuts'oane ho mamella hajoale(4s) | kA | 16,20,25,31.5,40,50 | |
E lekantsoe tlhoro e mamellang hajoale | kA | 40,50,63,80,100,125 | |
Tekanyo ea ts'ireletso | Enclosure IP4X, IP2X(VCB monyako o butswe) | ||
Bophahamo/botebo/bolelele) | mm | 650(800,1000) /1500(1300,1670,2000) /2300 | |
Boima ba 'mele | kg | 500 ~ 1200 |
Setšoantšo sa sebopeho sa cubicle 630A ~ 1250A

Setšoantšo sa sebopeho sa cubicle 1600A ~ 4000A

B.Main tekheniki parameters tafole bakeng sa 17.5kV switchgear
Che. | Lebitso | Yuniti | Lintlha | |
1 | Matla a lekantsoeng | kV | 15/17.5 | |
2 | Boemo bo lekantsoeng ba insulation | 1 mets ea maqhubu a matla a mamellang voltage (RMS) | kV | 50 |
Matla a mabone a mamella voltage (peak) | 95 | |||
3 | E lekantsoe hajoale | A | 630-4000 | |
4 | E lekanyelitsoe ho bula nako e khuts'oane | kA | 50 | |
5 | E lekantsoe maqhubu a matla | Hz | 50/60 | |
6 | E lekantsoe ka nako e khuts'oane ea ho etsa hajoale(peak) | kA | 130 | |
7 | E lekantsoe tlhoro e mamellang hajoale | kA | 130 | |
8 | E fuoe nako e khuts'oane ea ho mamella hajoale | kA | 50 | |
9 | Bophelo ba motlakase | linako | 20 | |
10 | E fuoe nako ea nako e khutšoanyane ea potoloho | s | 4 | |
11 | Bophelo ba mechine ea VCB | linako | 10000 | |
12 | Tekanyo ea tšireletso ea cubicle | Enclosure IP4X, IP2X(VCB monyako o butswe) | ||
13 | Bophahamo ba Outline (W*D*H) | mm | 800/1000*1500/1670*2300 | |
14 | Boima ba 'mele | kg | 500 ~ 1200 |
Litlhaloso tsa C.Technical bakeng sa 24kV switchgear
Ntho | Yuniti | Lintlha | |
Matla a lekantsoeng | kV | 24 | |
E lekantsoe khafetsa | Hz | 50/60 | |
E lekantsoe hajoale | A | 630,1250, 1600, 2500, 3150, 4000 | |
Boemo bo lekantsoeng ba insulation | 1min maqhubu a matla (mohato ho ea lefats'eng / ka har'a mabitso a bulehileng) | kV |
65 |
Tšusumetso ea lehalima e mamella voltage (mohato ho ea lefats'eng / ka har'a mabitso a bulehileng) | kV |
125 | |
E fuoe lintlha tsa nako e khuts'oane ho mamella hajoale(4s) | kA | 20, 25, 31,5 | |
E lekantsoe tlhoro e mamellang hajoale | kA | 50, 63, 80 | |
Tekanyo ea ts'ireletso | Sebaka: IP4X, monyako o butsoe: IP2X | ||
Bophahamo ba setšoantšo (bophara x botebo x bophahamo) | mm | 1000(800)x1820(1500)x2430(2300) | |
Boima ba 'mele | kg | 1200-1500 |
1. Matla a potoloho e khutšoanyane ea CT e tla nkoa ka thoko;
2. Sets'oants'o sa mohala o tsoang ka morao o tlameha ho ba le cubicle e eketsehileng.
Setšoantšo sa moralo oa sebopeho sa karolo ea GPN1-24kV setšoantšo sa phanele ea phepelo